Dit is een nieuwe analoog-digitale weegversterker met display. Deze indicator is inzetbaar voor diverse weeg applicaties o.a. afvulsystemen. Gestuurd via RS-485 interface met protocol Modbus RTU, kan ook gebruikt worden voor distributed I/O systemen
Dimensions :BT400: 106x90x58 mm ( L x H x D). Mounting on DIN
BT500: 96x48x120 mm ( L x H x D). Mounting onpanel, manhole: 92x44 Material : ABS Protection BT400(front) : IP-20 BT500(front): IP-51 Weight : 230 g Working temperature : -10 až +40°C Power supply : 24 VDC ± 15% Power equirement : 5 W. Dislay and setting : 6x 7 segment LED digit, height 1,44 mm -- 4x red status LED --- 4x membrane buttons. Conversion response : 50 Hz (without filtration) Internal discernment : 60.000 poits Sensibility : 0,02 µV/division Linearity :0,01% on the range Temperature effect :0,001% on the range/°C Converter A/D : 24 bit Decimal point : 0,0 - 0,00 - 0,000 optional. For 6 load cells (350 Ohmu) 4 or 6 wire Output interface RS-232, RS 422 or RS 485. 2 digital (logical) input (opto-izolated, 24 VDC PNP - requierement externalsupply) 2 digital output ( semiconductor relay, max. 24VDC/100 mA each) 1 analog output (0-10 VDC, max. resistance 10 kOhm or 4-20 mA , min. resistance 300 Ohm) Setting possible using buttons on front panel or through RS 232 interface and program INOVATION. Both direct or indirect calibration are possible (the second mentioned is suitable for calibration of forces, big containers e.g. which cannot be calibrated directly ). Power supply source for BT 400/500 Mod. 121 is recommended to be used
Dimensions :BT400: 106x90x58 mm ( L x H x D). Mounting on DIN
BT500: 96x48x120 mm ( L x H x D). Mounting onpanel, manhole: 92x44 Material : ABS Protection BT400(front) : IP-20 BT500(front): IP-51 Weight : 230 g Working temperature : -10 až +40°C Power supply : 24 VDC ± 15% Power equirement : 5 W. Dislay and setting : 6x 7 segment LED digit, height 1,44 mm -- 4x red status LED --- 4x membrane buttons. Conversion response : 50 Hz (without filtration) Internal discernment : 60.000 poits Sensibility : 0,02 µV/division Linearity :0,01% on the range Temperature effect :0,001% on the range/°C Converter A/D : 24 bit Decimal point : 0,0 - 0,00 - 0,000 optional. For 6 load cells (350 Ohmu) 4 or 6 wire Output interface RS-232, RS 422 or RS 485. 2 digital (logical) input (opto-izolated, 24 VDC PNP - requierement externalsupply) 2 digital output ( semiconductor relay, max. 24VDC/100 mA each) 1 analog output (0-10 VDC, max. resistance 10 kOhm or 4-20 mA , min. resistance 300 Ohm) Setting possible using buttons on front panel or through RS 232 interface and program INOVATION. Both direct or indirect calibration are possible (the second mentioned is suitable for calibration of forces, big containers e.g. which cannot be calibrated directly ). Power supply source for BT 400/500 Mod. 121 is recommended to be used